Сообщение от
Злой
а у меня в два раза больше за пол года
А часов сколько наработал? Мой 2007 часов, то есть парковались головки каждые 3 минуты работы.
Хотя возможно твой ноут в основном от батареи работает...
Нажми для просмотра
Код:
smartctl 5.41 2011-06-09 r3365 [i686-linux-3.2.0-41-generic-pae] (local build)
Copyright (C) 2002-11 by Bruce Allen, http://smartmontools.sourceforge.net
=== START OF INFORMATION SECTION ===
Device Model: HITACHI HTS545032B9A300
Serial Number: 101104PBN3044TG1NS7S
LU WWN Device Id: 5 000cca 66fc0c243
Firmware Version: PB3ZC61H
User Capacity: 320,072,933,376 bytes [320 GB]
Sector Size: 512 bytes logical/physical
Device is: Not in smartctl database [for details use: -P showall]
ATA Version is: 8
ATA Standard is: ATA-8-ACS revision 6
Local Time is: Fri May 10 22:06:41 2013 MSK
SMART support is: Available - device has SMART capability.
SMART support is: Enabled
=== START OF READ SMART DATA SECTION ===
SMART overall-health self-assessment test result: PASSED
General SMART Values:
Offline data collection status: (0x00) Offline data collection activity
was never started.
Auto Offline Data Collection: Disabled.
Self-test execution status: ( 0) The previous self-test routine completed
without error or no self-test has ever
been run.
Total time to complete Offline
data collection: ( 645) seconds.
Offline data collection
capabilities: (0x5b) SMART execute Offline immediate.
Auto Offline data collection on/off support.
Suspend Offline collection upon new
command.
Offline surface scan supported.
Self-test supported.
No Conveyance Self-test supported.
Selective Self-test supported.
SMART capabilities: (0x0003) Saves SMART data before entering
power-saving mode.
Supports SMART auto save timer.
Error logging capability: (0x01) Error logging supported.
General Purpose Logging supported.
Short self-test routine
recommended polling time: ( 2) minutes.
Extended self-test routine
recommended polling time: ( 106) minutes.
SCT capabilities: (0x003d) SCT Status supported.
SCT Error Recovery Control supported.
SCT Feature Control supported.
SCT Data Table supported.
SMART Attributes Data Structure revision number: 16
Vendor Specific SMART Attributes with Thresholds:
ID# ATTRIBUTE_NAME FLAG VALUE WORST THRESH TYPE UPDATED WHEN_FAILED RAW_VALUE
1 Raw_Read_Error_Rate 0x000b 100 100 062 Pre-fail Always - 0
2 Throughput_Performance 0x0005 100 100 040 Pre-fail Offline - 0
3 Spin_Up_Time 0x0007 142 142 033 Pre-fail Always - 2
4 Start_Stop_Count 0x0012 099 099 000 Old_age Always - 2353
5 Reallocated_Sector_Ct 0x0033 100 100 005 Pre-fail Always - 0
7 Seek_Error_Rate 0x000b 100 100 067 Pre-fail Always - 0
8 Seek_Time_Performance 0x0005 100 100 040 Pre-fail Offline - 0
9 Power_On_Hours 0x0012 096 096 000 Old_age Always - 2007
10 Spin_Retry_Count 0x0013 100 100 060 Pre-fail Always - 0
12 Power_Cycle_Count 0x0032 099 099 000 Old_age Always - 1769
191 G-Sense_Error_Rate 0x000a 100 100 000 Old_age Always - 0
192 Power-Off_Retract_Count 0x0032 100 100 000 Old_age Always - 1825505302
193 Load_Cycle_Count 0x0012 097 097 000 Old_age Always - 37711
194 Temperature_Celsius 0x0002 177 177 000 Old_age Always - 31 (Min/Max 8/40)
196 Reallocated_Event_Count 0x0032 100 100 000 Old_age Always - 0
197 Current_Pending_Sector 0x0022 100 100 000 Old_age Always - 0
198 Offline_Uncorrectable 0x0008 100 100 000 Old_age Offline - 0
199 UDMA_CRC_Error_Count 0x000a 200 200 000 Old_age Always - 0
223 Load_Retry_Count 0x000a 100 100 000 Old_age Always - 0
SMART Error Log Version: 1
No Errors Logged
SMART Self-test log structure revision number 1
Num Test_Description Status Remaining LifeTime(hours) LBA_of_first_error
# 1 Short offline Completed without error 00% 1414 -
# 2 Short offline Completed without error 00% 1249 -
# 3 Short offline Completed without error 00% 1223 -
# 4 Short offline Completed without error 00% 1145 -
# 5 Short offline Completed without error 00% 1077 -
# 6 Short offline Aborted by host 10% 1063 -
# 7 Short offline Completed without error 00% 1041 -
# 8 Short offline Completed without error 00% 902 -
# 9 Short offline Completed without error 00% 819 -
#10 Short offline Completed without error 00% 737 -
#11 Short offline Completed without error 00% 652 -
#12 Short offline Completed without error 00% 516 -
#13 Short offline Completed without error 00% 471 -
#14 Short offline Completed without error 00% 411 -
#15 Short offline Completed without error 00% 220 -
#16 Short offline Completed without error 00% 150 -
SMART Selective self-test log data structure revision number 1
SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS
1 0 0 Not_testing
2 0 0 Not_testing
3 0 0 Not_testing
4 0 0 Not_testing
5 0 0 Not_testing
Selective self-test flags (0x0):
After scanning selected spans, do NOT read-scan remainder of disk.
If Selective self-test is pending on power-up, resume after 0 minute delay.